-20°C Mini-Coolers, Cryo Coolers, Cryoware

-20°C Mini-Coolers

-20°C Mini-Coolers are manufactured from virgin, US FDA-21 CFR compliance Polycarbonate (PC). It acts as an alternate to ice buckets for keeping reagents and enzymes cool. All having a transparent non-filled clear Lid except 525060 which comes with a White Gel Filled Lid.

-20°C PCR Mini-Coolers should be pre-frozen at -20°C to -25°C for 24 hours before use. It maintains temperature below 1°C for approximately 5 hrs and -15°C for one hr.  It acts as an alternate to ice buckets for keeping reagents and enzymes cool.

Mini-Coolers (525030, 526030, 526040, 525060) also come with an adaptor which helps to fit 0.5 mL micro-centrifuge tubes into wells in a proper way.

Certificates..
Catalog No. Technical Data Well Compatibility Temperature Specification Lid Packing Details
525110

96 0.1/0.2 mL PCR Tubes / strips / Plates Below -15°C for one hour. Without gel PK 1
  525110
Description: -20°C PCR Mini-coolers with transparent lid, PC
Product Type: PCR Mini-coolers
Raw Material: Polycarbonate (PC) body with aluminium metal block
Transparency: Bottom: Opaque, Lid: Transparent
Colour: Bottom: Yellow, Lid: Natural
Mini Cooler Length: 227 mm
Mini Cooler Width: 165 mm
Lid Height: 40 mm
Base Height: 80 mm
Total Height with Lid: 113 mm
Well Array: 8 x12
Well Id: 6.5 mm
Compatible with Tubes/Strips/Plates All types 0.2 mL PCR Tubes/Strips, 0.1 mL PCR Plate (613010) & 0.2 mL PCR Plate (612010 & 612020).
Uses & Features: Should be pre-frozen at -20°C to -25°C for 24 hours before use. It maintains temperature below 1°C for approximately 5 hrs and -15°C for one hr. It acts as an alternate to ice buckets for keeping reagents and enzymes cool.
525030

12 0.5/1.5/2.0 mL Tubes Below -15°C for one hour. Without gel PK 1
  525030
Description: -20°C PCR Mini-coolers with transparent lid, PC
Product Type: PCR Mini-coolers
Raw Material: Polycarbonate (PC) body with aluminium metal block
Transparency: Bottom: Opaque, Lid: Transparent
Colour: Bottom: Yellow, Lid: Natural
Bottom Max Length: 144.5 mm
Bottom Max Width: 101.4 mm
Bottom Max Height: 71.5 mm
Lid Max Length: 122.5 mm
Lid Max Width: 101 mm
Lid Height: 33.5 mm
Total Height with Lid: 98.6 mm
Well Array: 3 x 4
Well Id: 12 mm
Alphanumeric: Yes, Molded
Compatible with Tube Sizes 0.5 mL (with insert), 1.5 mL & 2 mL
Uses & Features: Freeze -20°C Mini Cooler for 24 hours at -20°C to -25°C before use. It maintains temperature below 1°C for approximately 5 hrs and -15°C for one hr. Thaw the unit once a month to remove any ice buildup.
526030

32 0.5/1.5/2.0 mL Tubes Below -15°C for one hour. Without gel PK 1
  526030
Description: -20°C PCR Mini-coolers with transparent lid, PC
Product Type: PCR Mini-coolers
Raw Material: Polycarbonate (PC) body with aluminium metal block
Transparency: Bottom: Opaque, Lid: Transparent
Colour: Bottom: Yellow, Lid: Natural
Bottom Max Length: 224 mm
Bottom Max Width: 128 mm
Bottom Max Height: 72 mm
Lid Max Length: 226 mm
Lid Max Width: 127 mm
Lid Height: 34 mm
Total Height with Lid: 98 mm
Well Array: 4 x 8
Well Id: 12 mm
Alphanumeric: Yes, Molded
Compatible with Tube Sizes 0.5 mL (with insert), 1.5 mL & 2 mL
Uses & Features: Freeze -20°C Mini Cooler for 24 hours at -20°C to -25°C before use. It maintains temperature below 1°C for approximately 5 hrs and -15°C for one hr.  Thaw the unit once a month to remove any ice buildup.
526040

20 0.5/1.5/2.0 mL Tubes Below -15°C for one hour. Without gel PK 1
  526040
Description: -20°C PCR Mini-coolers with transparent lid, PC
Product Type: PCR Mini-coolers
Raw Material: Polycarbonate (PC) body with aluminium metal block
Transparency: Bottom: Opaque, Lid: Transparent
Colour: Bottom: Yellow, Lid: Natural
Bottom Max Length: 224 mm
Bottom Max Width: 163 mm
Bottom Max Height: 80 mm
Lid Max Length: 210 mm
Lid Max Width: 160 mm
Lid Height: 38 mm
Total Height with Lid: 112 mm
Well Array: 4 x 5
Well Id: 12 mm
Alphanumeric: Yes, Molded
Compatible with Tube Sizes 0.5 mL (with insert), 1.5 mL & 2 mL
Uses & Features: Freeze -20°C Mini Cooler for 24 hours at -20°C to -25°C before use. It maintains temperature below 1°C for approximately 5 hrs and -15°C for one hr. Thaw the unit once a month to remove any ice buildup.
525060

32 0.5/1.5/2.0 mL Tubes Below -15°C for one and a half hour. filled with gel PK 1
  525060
Description: -20°C PCR Mini-coolers with Gel Filled Cover, PC
Product Type: PCR Mini-coolers
Raw Material: Polycarbonate (PC) body with aluminium metal block
Transparency: Bottom: Opaque, Lid: Opaque
Colour: Bottom: Yellow, Lid: White
Mini Cooler Length: 240 mm
Mini Cooler Width: 130 mm
Lid Height: 47 mm
Base Height: 70 mm
Total Height with Lid: 111 mm
Well Array: 4 x 8
Well Id: 12.1 mm
Compatible with Tubes 1.5 mL
Uses & Features: Freeze -20°C Mini Cooler for 24 hours at -20°C to -25°C before use. It maintains temperature below 1°C for approximately 5 hrs and -15°C for one and a half hr. Thaw the unit once a month to remove any ice buildup.
525113

12 5 mL centrifuge Tube Below -15°C for one hour. Without gel PK 1
  525113
Description: -20°C PCR Mini-cooler for 5 mL Micro Centrifuge Tube, PC
Product Type: PCR Mini-coolers
Raw Material: Polycarbonate (PC) body with aluminium metal block
Transparency: Bottom: Opaque, Lid: Transparent
Colour: Bottom: Yellow, Lid: Natural
Bottom Max Length: 195 mm
Bottom Max Width: 165 mm
Bottom Max Height: 80.5 mm
Lid Max Length: 212 mm
Lid Max Width: 162 mm
Lid Height: 37.8 mm
Total Height with Lid: 112.2 mm
Well Array: 3 x 4
Well Id: 18.25 mm
Alphanumeric: Yes, Molded
Compatible with Tube Sizes 5 mL
Uses & Features: Freeze -20°C Mini Cooler for 24 hours at -20°C to -25°C before use. It maintains temperature below 1°C for approximately 5 hrs and -15°C for one hr. Thaw the unit once a month to remove any ice buildup.

  • Key Features:
    • Material conforms to US FDA 21 CFR.
    • Suitable for 0.1 mL/ 0.2 mL PCR tubes, strips and plates.
    • Mini-Coolers (525030, 526030, 526040, 525060) also come with an adaptor which helps to fit 0.5 mL micro-centrifuge tubes into wells in a proper way.
    • It maintains temperature below 1°C for approximately 5 hrs and -15°C for one hr.
    • PCR Mini-coolers should be pre-frozen at -20°C to -25°C for 24 hours before use.
    • Acts as an alternate to ice buckets for keeping reagents and enzymes cool.

Description

  • Key Features:
    • Material conforms to US FDA 21 CFR.
    • Suitable for 0.1 mL/ 0.2 mL PCR tubes, strips and plates.
    • Mini-Coolers (525030, 526030, 526040, 525060) also come with an adaptor which helps to fit 0.5 mL micro-centrifuge tubes into wells in a proper way.
    • It maintains temperature below 1°C for approximately 5 hrs and -15°C for one hr.
    • PCR Mini-coolers should be pre-frozen at -20°C to -25°C for 24 hours before use.
    • Acts as an alternate to ice buckets for keeping reagents and enzymes cool.