Genomics & PCR Consumables

PCR Mini-Coolers

PCR Mini-Coolers are manufactured from virgin, US FDA-21 CFR compliance Polycarbonate (PC) / Polypropylene (PP). It is also used to keep PCR tubes, 8-strips or 96 Well PCR plates at low temperatures during sample preparation and handling. It acts as an alternate to ice buckets for keeping reagents and enzymes cool.

MAGICOOLTM Mini-coolers should be kept at -20°C to -25°C in inverted condition for 24 hours before use. It keeps samples at 4°C for approximately 3 hrs. When temperature exceeds +7°C, it indicates by changing colour from violet to pink.

-20°C PCR Mini-coolers with transparent lid should be pre-frozen at -20°C to -25°C for 24 hours before use. It maintains temperature below 1°C for approximately 5 hrs. It acts as an alternate to ice buckets for keeping reagents and enzymes cool.

Both Mini-Coolers are suitable for individual PCR Tubes, 8-strips or 96-Well PCR Plates.

Certificates..
Catalog No. Technical Data Well Compatibility Material Packing Details
241002

96 0.1/0.2 mL PCR Tubes / strips / Plates Polypropylene filled with non-toxic insulating solution PK 12
241002
Description: MAGICOOL PCR Mini-Cooler, PP
Product Type: PCR Mini-coolers
Raw Material: Polypropylene (PP): FDA -21 CFR compliance
Mini Cooler Length: 127.8 mm
Mini Cooler Width: 86 mm
Total Height: 29 mm
Well ID: 6 mm
Compatible Tubes: 0.1 mL/ 0.2 mL PCR tubes, strips and plates.
Well Array: 8×12
Uses & Features: Acts as thermochromic self-indicator. When temperature exceeds +7°C, it indicates by changing colour from violet to pink. It keeps samples at 4°C for approximately 3 hrs. Used for preparation of PCR reaction.
525110

96 0.1/0.2 mL PCR Tubes / strips / Plates Polycarbonate filled with non-toxic gel PK 6
525110
Description: -20°C PCR Mini-coolers with transparent lid, PC
Product Type: PCR Mini-coolers
Raw Material: Polycarbonate (PC) body with aluminium metal block
Transparency: Bottom: Opaque, Lid: Transparent
Colour: Bottom: Yellow, Lid: Natural
Mini Cooler Length: 227 mm
Mini Cooler Width: 165 mm
Lid Height: 40 mm
Base Height: 80 mm
Total Height with Lid: 113 mm
Well Array: 8×12
Well Id: 6.5 mm
Compatible with Tubes/Strips/Plates All types 0.2 mL PCR Tubes/Strips, 0.1 mL PCR Plate (613010) & 0.2 mL PCR Plate (612010 & 612020).
Uses & Features: Should be pre-frozen at -20°C to -25°C for 24 hours before use. It maintains temperature below 1°C for approximately 5 hrs. It acts as an alternate to ice buckets for keeping reagents and enzymes cool.
525030

12 1.5 mL Tubes Polycarbonate filled with non-toxic gel PK 6
525030
Description: -20°C PCR Mini-coolers with transparent lid, PC
Product Type: PCR Mini-coolers
Raw Material: Polycarbonate (PC) body with aluminium metal block
Transparency: Bottom: Opaque, Lid: Transparent
Colour: Bottom: Yellow, Lid: Natural
Bottom Max Length: 144.5 mm
Bottom Max Width: 101.4 mm
Bottom Max Height: 71.5 mm
Lid Max Length: 122.5 mm
Lid Max Width: 101 mm
Lid Height: 33.5 mm
Total Height with Lid: 98.6 mm
Well Array: 3 x 4
Well Id: 12 mm
Alphanumeric: Yes, Molded
Compatible with Tube Sizes 0.5 mL (with insert), 1.5 mL & 2 mL
Uses & Features: Freeze -20°C Mini Cooler for 24 hours at -20°C to -25°C before use. At room temperature these units maintain below -15°C temperature for one hour. Thaw the unit once a month to remove any ice buildup.
526030

32 1.5 mL Tubes Polycarbonate filled with non-toxic gel PK 6
526030
Description: -20°C PCR Mini-coolers with transparent lid, PC
Product Type: PCR Mini-coolers
Raw Material: Polycarbonate (PC) body with aluminium metal block
Transparency: Bottom: Opaque, Lid: Transparent
Colour: Bottom: Yellow, Lid: Natural
Bottom Max Length: 224 mm
Bottom Max Width: 128 mm
Bottom Max Height: 72 mm
Lid Max Length: 226 mm
Lid Max Width: 127 mm
Lid Height: 34 mm
Total Height with Lid: 98 mm
Well Array: 4 x 8
Well Id: 12 mm
Alphanumeric: Yes, Molded
Compatible with Tube Sizes 0.5 mL (with insert), 1.5 mL & 2 mL
Uses & Features: Freeze -20°C Mini Cooler for 24 hours at -20°C to -25°C before use. At room temperature these units maintain below -15°C temperature for one hour. Thaw the unit once a month to remove any ice buildup.
526040

20 1.5 mL Tubes Polycarbonate filled with non-toxic gel PK 6
526040
Description: -20°C PCR Mini-coolers with transparent lid, PC
Product Type: PCR Mini-coolers
Raw Material: Polycarbonate (PC) body with aluminium metal block
Transparency: Bottom: Opaque, Lid: Transparent
Colour: Bottom: Yellow, Lid: Natural
Bottom Max Length: 224 mm
Bottom Max Width: 163 mm
Bottom Max Height: 80 mm
Lid Max Length: 210 mm
Lid Max Width: 160 mm
Lid Height: 38 mm
Total Height with Lid: 112 mm
Well Array: 4 x 5
Well Id: 12 mm
Alphanumeric: Yes, Molded
Compatible with Tube Sizes 0.5 mL (with insert), 1.5 mL & 2 mL
Uses & Features: Freeze -20°C Mini Cooler for 24 hours at -20°C to -25°C before use. At room temperature these units maintain below -15°C temperature for one hour. Thaw the unit once a month to remove any ice buildup.
525060

32 - Polycarbonate filled with non-toxic gel PK 6
525060
Description: -20°C PCR Mini-coolers with Gel Filled Cover, PC
Product Type: PCR Mini-coolers
Raw Material: Polycarbonate (PC) body with aluminium metal block
Transparency: Bottom: Opaque, Lid: Opaque
Colour: Bottom: Yellow, Lid: White
Mini Cooler Length: 240 mm
Mini Cooler Width: 130 mm
Lid Height: 47 mm
Base Height: 70 mm
Total Height with Lid: 111 mm
Well Array: 4 x 8
Well Id: 12.1 mm
Compatible with Tubes 1.5 mL
Uses & Features: Freeze -20°C Mini Cooler for 24 hours at -20°C to -25°C before use. At room temperature these units maintain below -15°C temperature for one hour. Thaw the unit once a month to remove any ice buildup.

Key Features:

  • Material conforms to US FDA 21 CFR.
  • Suitable for 0.1 mL/ 0.2 mL PCR tubes, strips and plates.
  • When temperature exceeds +7°C, MAGICOOL Mini-coolers indicates by changing colour from violet to pink.
  • PCR Mini-coolers should be pre-frozen at -20°C to -25°C for 24 hours before use.
  • Acts as an alternate to ice buckets for keeping reagents and enzymes cool.

Description

Key Features:

  • Material conforms to US FDA 21 CFR.
  • Suitable for 0.1 mL/ 0.2 mL PCR tubes, strips and plates.
  • When temperature exceeds +7°C, MAGICOOL Mini-coolers indicates by changing colour from violet to pink.
  • PCR Mini-coolers should be pre-frozen at -20°C to -25°C for 24 hours before use.
  • Acts as an alternate to ice buckets for keeping reagents and enzymes cool.